In the Field · Part 4

Water heaters II: tankless and heat pump. Gas sizing, venting, condensate, the 2025 Energy Code direction, and where the gas-ban ordinances stand

Lesson 6 of 27~13 minFree previewCurrent as of September 2026Leer en español

The two water heaters that are not a tank each turn a four-hour swap into a design job. A gas tankless unit draws four to six times the input of the tank it replaces, so the gas line, the venting, and the condensate drain are the job, not the heater. A heat pump water heater draws almost no gas and instead needs a 240-volt circuit, air, a place for the condensate, and a customer who understands recovery time. Both are where California's energy policy is pointed: the 2025 Energy Code makes heat pump water heating the prescriptive baseline for new homes and additions. And both are the subject of local politics: the Berkeley gas ban was struck down in federal court in 2023 and repealed, and the South Coast air district's proposed zero-NOx water heater rule was voted down in June 2025. This lesson gives the method for each unit and the current state of the rules so the sale is honest.

What the full lesson covers

  • Tankless gas: size the gas line for the unit's full input on the longest run of the whole system (CPC 1215.1.1); most 1/2-inch branches that fed a 40,000 BTU tank cannot feed a 150,000 to 199,000 BTU tankless, and a new 3/4-inch or 1-inch run from the meter is normal.
  • Tankless venting is Category III or IV per the listing, with the listed vent material, terminations, and clearances; condensing units produce acidic condensate that goes to an approved drain (CPC 814.1), through a neutralizer where the AHJ or the manufacturer requires it.
  • Heat pump: a 240-volt dedicated circuit by an electrician, the manufacturer's minimum air volume or ducting, a condensate drain, and a location where the cool exhaust air and the compressor noise are acceptable.
  • Policy: the 2025 Energy Code (effective January 1, 2026) makes heat pump water heating the prescriptive baseline for new single-family construction and additions; replacing an existing gas heater with gas in an existing home remains lawful under state law and the compliance forms for alterations govern.
  • Gas bans: Berkeley's ordinance was held preempted by federal law (9th Cir. 2023) and repealed; cities have moved to other approaches; the SCAQMD zero-NOx water heater amendment failed on June 6, 2025. Check the city and the air district before telling a customer what they may or may not install.

Unlock the full lesson

This is the public summary. The full lesson has the method, the worked cases, the checklists and the templates:

  • All in-depth lessons, exam prep and After the License
  • 1,000+ practice questions
  • AI tutor (100 messages included)
  • 14+ hours of audio lessons
  • Full-length practice exams
  • Pass guarantee
Start Free — Create Account$149 one-time · lifetime access · no subscription

Already have an account? Sign in

More lessons in The Field: Method, Code, and Cases

Get Help