In the Field · Part 4
Fixtures and conservation: CALGreen flow rates, SB 407 retrofit-on-alteration and disclosure-on-sale, 1.28 gpf, and the ADA basics a plumber needs
California's fixture rules decide what a plumber may install and what a plumber must replace. The plumbing code sets the flow rates for anything new: 1.28 gallons per flush, 1.8 gallons per minute at the showerhead and the kitchen sink, 1.2 at the bathroom sink. And a separate law, SB 407 in the Civil Code, reaches back into every house built before 1994: any permitted alteration triggers replacement of every old toilet, showerhead, and faucet in the house as a condition of the final inspection, and every seller must disclose whether old fixtures remain. This lesson gives both sets of numbers with their sections, explains what the SB 407 trigger means for a plumber pulling a permit in an older house, and covers the accessibility basics that apply the moment the customer is a business.
What the full lesson covers
- New fixture maximums (2025 CPC, from CALGreen): water closets 1.28 gpf; showerheads 1.8 gpm at 80 psi, WaterSense; residential lavatory faucets 1.2 gpm at 60 psi (minimum 0.8 at 20 psi); kitchen faucets 1.8 gpm with a temporary 2.2 boost; public lavatory faucets 0.5 gpm.
- SB 407 (Civil Code 1101.1 to 1101.8) applies to property built on or before January 1, 1994. Noncompliant means a toilet over 1.6 gpf, a urinal over 1.0 gpf, a showerhead over 2.5 gpm, or an interior faucet over 2.2 gpm.
- In a single-family house, any permitted building alteration or improvement requires replacement of all noncompliant fixtures as a condition of final permit approval (1101.4(a)); all were to be replaced by January 1, 2017 (1101.4(b)); sellers must disclose in writing (1101.4(c)). Building departments enforce (a) at final; your permit can be the trigger.
Unlock the full lesson
This is the public summary. The full lesson has the method, the worked cases, the checklists and the templates:
- All in-depth lessons, exam prep and After the License
- 1,200+ practice questions
- AI tutor (100 messages included)
- 18+ hours of audio lessons
- Full-length practice exams
- Pass guarantee
More lessons in The Field: Method, Code, and Cases
- 1The diagnostic method: verify, isolate, cheapest test first, cause not symptom, the options ladder, document
- 2Permits: when one is required, what is exempt, pulling it online, the inspection sequence, what inspectors look for, and handling corrections
- 3Daily-use code: drainage slope, venting, water sizing, cleanouts, trap arms, and fixture units, with the section for each
- 4Gas piping in practice: sizing, CSST bonding, the pressure test, appliance connectors and shutoffs, sediment traps, and seismic shutoff valves