60 free questions with answers, explanations and the official source for each. Answer one to see why. No sign-up.
CSLB weight: about 17%
0 of 0 right · 60 to go
1 / 60
Under Title 8 Section 3276 (applied to construction by Section 1675), when a portable ladder is used to reach an upper landing such as the rim of a trench, what is the minimum distance its side rails must extend above that landing?
Title 8 Section 3276: when portable ladders are used for access to an upper landing surface, the side rails shall extend not less than 36 inches above that surface, or the ladder shall be secured at its top. Section 1675(b) applies Section 3276 to portable ladders used in construction.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 3276
2 / 60
Under Title 8 Section 1670, what does the section say about body belts in a personal fall arrest system?
Title 8 Section 1670(b): except as permitted in subsections (c) and (d), body belts shall not be used as part of a personal fall arrest system. A body harness distributes the fall arrest forces over the thighs, pelvis, waist, chest and shoulders.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1670
3 / 60
A plumber will cut out and remove old piping joined with lead solder. Under Title 8 Section 1532.1, does the construction lead standard apply to this work?
Title 8 Section 1532.1 applies to all construction work where an employee may be occupationally exposed to lead, and its list of construction work includes removal or encapsulation of materials containing lead.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1532.1
4 / 60
At what depth is a ladder or safe means of exit required for a trench according to Cal/OSHA?
Cal/OSHA Section 1541(c)(2): a stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet or more in depth, so as to require no more than 25 feet of lateral travel for employees.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1541
5 / 60
A plumber is torch brazing copper. Under Title 8 Section 3382 Table EP-1, which filter lens shade number is listed for torch brazing?
Title 8 Section 3382 Table EP-1 lists filter lens shade 3 or 4 for torch brazing. The table is used as a guide, and a denser shade may be used to suit the individual.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 3382
6 / 60
A plumber is using a 20-pound cylinder of propane (a flammable gas) for a torch on the job site. Under Title 8 Section 1922, what fire extinguisher must be provided?
Title 8 Section 1922: a fire extinguisher rated not less than 10B shall be provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the job site.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1922
7 / 60
A plumber will enter a septic tank (a permit space), and the employer has selected non-entry rescue. Under Title 8 Section 1960, what must each authorized entrant use?
Title 8 Section 1960: whenever non-entry rescue is selected, retrieval systems are used whenever an authorized entrant enters a permit space. Each authorized entrant shall use a chest or full body harness, with a retrieval line attached at the center of the entrant's back near shoulder level or above the entrant's head.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1960
8 / 60
Under Title 8 Section 5194(g)(2), which of these is a required section heading of a safety data sheet (SDS)?
Title 8 Section 5194(g)(2): a safety data sheet includes, in order, Section 1 Identification, Section 2 Hazard(s) identification, Section 3 Composition/information on ingredients, Section 4 First-aid measures, and further numbered sections.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 5194
9 / 60
An employee who wears prescription eyeglasses needs eye protection. Under Title 8 Section 3382, which of these is an acceptable form of that eye protection?
Title 8 Section 3382: where employees need vision correction, eye protection is provided as safety spectacles with suitable corrected lenses, safety goggles designed to fit over spectacles, or protective goggles with corrective lenses mounted behind the protective lenses.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 3382
10 / 60
Under Title 8 Section 2405.4, which receptacle outlets on a construction site must have approved ground-fault circuit interrupters for personnel protection?
Title 8 Section 2405.4: all 120-volt, AC, single-phase, 15- and 20-ampere receptacle outlets on construction sites which are not a part of the permanent wiring of the building or structure and which are in use by employees shall have approved ground-fault circuit interrupters for personnel protection.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 2405.4
11 / 60
Under Title 8 Section 1670, an anchorage for personal fall arrest equipment must be capable of supporting at least how much per employee attached (unless designed under a qualified person as part of a complete system)?
Title 8 Section 1670: anchorages used for personal fall arrest equipment shall be independent of any anchorage used to support or suspend platforms and capable of supporting at least 5,000 pounds per employee attached, or be designed, installed, and used under the supervision of a qualified person as part of a complete system.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1670
12 / 60
Under the Title 8 Section 1540 definitions, what is a shield (shield system, often called a trench box)?
Title 8 Section 1540: a shield (shield system) is a structure that is able to withstand the forces imposed on it by a cave-in and thereby protect employees within the structure. Shields can be permanent or portable and moved along as work progresses.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1540
13 / 60
A confined space test reads oxygen 18%, flammable gas 35% of the LFL, H2S 0 ppm. Under the Title 8 Section 1951 definitions, can work proceed?
Title 8 Section 1951: a hazardous atmosphere includes flammable gas, vapor, or mist in excess of 10 percent of its lower flammable limit, and an oxygen deficient atmosphere contains less than 19.5 percent oxygen by volume. Both readings are hazardous.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1951
14 / 60
Under Title 8 Section 3381, which protective helmet impact type is intended to reduce the force of impact from a blow to the top or sides of the head?
Title 8 Section 3381: Type I helmets are intended to reduce the force of impact from a blow only to the top of the head. Type II helmets are intended to reduce the force of impact resulting from a blow to the top or sides of the head.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 3381
15 / 60
Under Title 8 Section 1743, acetylene shall not be generated or utilized at a pressure in excess of what?
Title 8 Section 1743(b): acetylene shall not be generated or utilized at a pressure in excess of 15 pounds per square inch gauge pressure, except acetylene dissolved in a suitable solvent and stored in approved cylinders.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1743
16 / 60
Title 8 Section 3385 (foot protection) incorporates which standard for protective safety-toe footwear?
Title 8 Section 3385 incorporates ASTM F2413, Standard Specification for Performance Requirements for Foot Protection. Older footwear could instead meet ANSI Z41. ANSI Z87.1 is eye and face protection; ANSI Z89.1 is head protection.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 3385
17 / 60
A plumber's harness and lanyard stopped a real fall from a roof yesterday, and the gear looks undamaged. Under Title 8 Section 1670, what must be done with it?
Title 8 Section 1670: any lanyard, safety belt, harness, dropline, lifeline or other component subjected to in-service loading (loading like a real fall) shall be immediately removed from service and shall not be used again for employee safeguarding.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1670
18 / 60
During a shift, the competent person notices a crack in a shoring brace (an indication of failure of a protective system). Under Title 8 Section 1541(k), what must be done?
Title 8 Section 1541(k): where the competent person finds evidence of a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees shall be removed from the hazardous area until the necessary precautions have been taken to ensure their safety.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1541
19 / 60
Under the Title 8 Section 1529 definitions, when is a material asbestos-containing material (ACM)?
Title 8 Section 1529: asbestos-containing material (ACM) means any material containing more than one percent asbestos.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1529
20 / 60
A crew digs a long, narrow excavation for a building sewer. Under Title 8 Section 1540, what bottom width may an excavation have and still be defined as a trench?
Title 8 Section 1540 defines a trench as a narrow excavation: in general the depth is greater than the width, but the width of a trench (measured at the bottom) is not greater than 15 feet.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1540
21 / 60
A backhoe (digging equipment) is lowering a length of ductile iron pipe into a trench on a chain. Under Title 8 Section 1541, what is the rule for employees near the suspended pipe?
Title 8 Section 1541: no employee shall be permitted underneath loads handled by lifting or digging equipment.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1541
22 / 60
An excavator is about to lift a trench shield vertically to reposition it along the sewer trench. Under Title 8 Section 1541.1, what applies to the pipe layers?
Title 8 Section 1541.1: employees shall not be allowed in shields when shields are being installed, removed, or moved vertically.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1541.1
23 / 60
A trench box (shield) sits in the vertical lower part of a trench whose upper part is sloped back (a compound excavation). Under Title 8 Section 1541.1, how far must the sides of the shield extend above the vertical walls?
Title 8 Section 1541.1: the sides of the shield shall extend a minimum of 18 inches above the vertical walls of compound excavations.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1541.1
24 / 60
What is the maximum slope angle (angle of repose) for Type A soil according to Cal/OSHA standards?
Type A soil has a maximum allowable slope of 3/4 horizontal to 1 vertical, which is 53 degrees. (1:1, or 45 degrees, is the Type B limit.)
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1541.1 App B
25 / 60
Under the scope of Title 8 Section 5095 (Article 105, control of noise exposure), which sections are construction operations exempt from?
Title 8 Section 5095: agriculture, construction, and oil and gas well drilling and servicing operations are exempt from the provisions of Sections 5097 through 5100.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 5095
26 / 60
Under Title 8 Section 1958, what is the role of the attendant in a permit-required confined space entry?
Title 8 Section 1958: each attendant continuously maintains an accurate count of authorized entrants, remains outside the permit space during entry operations until relieved by another attendant, communicates with entrants, orders evacuation when conditions require it, and summons rescue and other emergency services as soon as entrants may need assistance.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1958
27 / 60
A trench is dug in a downtown area where space is limited and sloping is not feasible. Under Title 8 Sections 1540 and 1541.1, which protective system fits?
Title 8 Section 1541.1 provides for support systems, shield systems, and other protective systems in place of sloping. Section 1540 defines a shield as a structure able to withstand the forces of a cave-in and protect employees within it.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1541.1
28 / 60
A gas detector reading before entering a septic tank (a permit space) shows oxygen at 17.8%. Under Title 8 Sections 1951 and 1953, what must happen before entry?
Title 8 Section 1951: an oxygen deficient atmosphere contains less than 19.5 percent oxygen by volume. Section 1953 requires purging, inerting, flushing, or ventilating the permit space as necessary to eliminate or control atmospheric hazards.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1951
29 / 60
A plumber cuts out old piping joined with lead solder. Under Title 8 Section 1532.1, what is the permissible exposure limit (PEL) for airborne lead, calculated as an 8-hour time-weighted average?
Title 8 Section 1532.1: the employer shall ensure that no employee is exposed to an airborne concentration of lead greater than 10 micrograms per cubic meter of air, calculated as an 8-hour time-weighted average (TWA).
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1532.1
30 / 60
A plumber finds a ladder rung slightly bent. Under Title 8 Section 3276, may the ladder be used?
Title 8 Section 3276: ladders that have developed defects shall be withdrawn from service for repair or destruction and tagged or marked "Dangerous, Do Not Use". Ladders with broken or missing steps, rungs, cleats, safety feet, side rails, or other defects shall not be used.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 3276
31 / 60
A plumber must lay pipe in a 6-foot-deep trench cut through an old landfill, where a hazardous atmosphere could reasonably be expected. Under Title 8 Section 1541, what is required before employees enter the trench?
Title 8 Section 1541: where a hazardous atmosphere could reasonably be expected to exist, such as in excavations in landfill areas, the atmosphere in the excavation shall be tested before employees enter excavations greater than 4 feet in depth.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1541
32 / 60
Under CPC 604.2, the lead content of solder and flux used in piping that conveys water for human consumption shall be not more than what?
CPC 604.2: for solder and flux, the lead content shall be not more than 0.2 percent where used in piping systems that convey or dispense water for human consumption.
Source: California Plumbing Code (CCR Title 24, Part 5) (2025) 604.2
33 / 60
A plumber works with organic solvent vapors. Under Title 8 Section 5144, which respirators may the employer provide for protection against gases and vapors?
Title 8 Section 5144: for protection against gases and vapors, the employer shall provide an atmosphere-supplying respirator, or an air-purifying respirator that has an end-of-service-life indicator certified by NIOSH for the contaminant or, if none fits, a change schedule for canisters and cartridges.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 5144
34 / 60
Under Title 8 Section 1960, what must an employer evaluate before designating a rescue service for a permit space entry?
Title 8 Section 1960(a): an employer who designates rescue and emergency services shall evaluate a prospective rescuer's ability to respond to a rescue summons in a timely manner, considering the hazards, and the rescue service's proficiency with rescue-related tasks and equipment.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1960
35 / 60
A plumbing contractor uses an assured equipment grounding conductor program on its jobs. Under Title 8 Section 2405.4, besides the tests before first use and after repairs, how often must the required tests be repeated on extension cord sets that are moved around the site?
Title 8 Section 2405.4 assured equipment grounding conductor program: the tests shall be performed at intervals not to exceed three (3) months, except that cord sets and receptacles which are fixed and not exposed to damage shall be tested at intervals not exceeding 6 months.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 2405.4
36 / 60
Before handling a new chemical product, you check its safety data sheet for the required personal protection. Under Title 8 Section 5194(g)(2), which SDS section covers exposure controls/personal protection?
Title 8 Section 5194(g)(2): SDS Section 8 is Exposure controls/personal protection. Section 2 is Hazard(s) identification, Section 4 is First-aid measures, and Section 7 is Handling and storage.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 5194
37 / 60
A plumber will solder copper and handle hot pipe, exposing the hands to thermal burns. Under Title 8 Section 3384, what must the employer do about hand protection?
Title 8 Section 3384: employers shall select, provide and require employees to use appropriate hand protection when employee's hands are exposed to hazards such as cuts, chemical burns, thermal burns, and harmful temperature extremes.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 3384
38 / 60
An excavation in Type A soil is 10 feet deep and will be open for less than 24 hours (short term). Under Title 8 Section 1541.1 Appendix B, what short-term maximum allowable slope may be used?
Title 8 Section 1541.1 Appendix B: a short-term maximum allowable slope of 1/2H:1V (63 degrees) is allowed in excavations in Type A soil that are 12 feet or less in depth. Short term means an excavation open 24 hours or less.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1541.1 App B
39 / 60
A plumber must work from a ladder next to an open panel with unprotected energized electrical conductors. Under Title 8 Section 3276, what kind of ladder must be used?
Title 8 Section 3276: non-conductive ladders shall be used in locations where the ladder or user may contact unprotected energized electrical conductors or equipment.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 3276
40 / 60
A plumber feels overheated and takes a preventative cool-down rest in the shade. Under Title 8 Section 3395, when may the plumber be ordered back to work?
Title 8 Section 3395: an employee who takes a preventative cool-down rest shall not be ordered back to work until any signs or symptoms of heat illness have abated, but in no event less than 5 minutes in addition to the time needed to access the shade.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 3395
41 / 60
Under Title 8 Section 2405.4, how must an employer protect employees who use cord-connected tools on construction sites?
Title 8 Section 2405.4(b): to protect employees on construction sites, the employer uses ground-fault circuit interrupters as in subsection (c), an assured equipment grounding conductor program as in subsection (d), or both, in addition to equipment grounding conductors.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 2405.4
42 / 60
A plumber cuts out old joints made with lead solder. According to Title 8 Section 1532.1 Appendix A, which route is generally the most important source of occupational lead absorption?
Title 8 Section 1532.1 Appendix A: when lead is scattered in the air as a dust, fume or mist it can be inhaled, and inhalation of airborne lead is generally the most important source of occupational lead absorption. Lead is not significantly absorbed through the skin.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1532.1 App A
43 / 60
Under Title 8 Section 1955, what does the written entry permit for a permit-required confined space do?
Title 8 Section 1955: the entry permit documents compliance and authorizes entry to a permit space. It identifies the space, the purpose and duration, the entrants and attendants, the hazards, the measures used to isolate and control them, the acceptable entry conditions, the test results, and the rescue and emergency services.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1955
44 / 60
A plumber cuts out an old lead service line. Under Title 8 Section 1532.1, what does 'altering or disturbing' lead-containing material mean?
Title 8 Section 1532.1: altering or disturbing means subjecting to a process that may result in the release of lead dust, lead mist, lead fume, or other lead particles. The listed processes include cutting, torch cutting, torch soldering and brazing.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1532.1
45 / 60
Under Title 8 Section 342, how soon must an employer report an employee's serious injury or illness to Cal/OSHA (the Division of Occupational Safety and Health)?
Title 8 Section 342: every employer shall report immediately to the Division any serious injury or illness, or death, of an employee. Immediately means as soon as practically possible but not longer than 8 hours after the employer knows or with diligent inquiry would have known.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 342
46 / 60
Under Title 8 Section 1951, a hazardous atmosphere in a confined space includes flammable gas, vapor, or mist in excess of what percent of its lower flammable limit (LFL)?
Title 8 Section 1951: a hazardous atmosphere includes flammable gas, vapor, or mist in excess of 10 percent of its lower flammable limit (LFL), among other causes such as oxygen deficiency.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1951
47 / 60
Under Title 8 Section 1541.1 Appendix A, which of the following is Type C soil?
Title 8 Section 1541.1 Appendix A: Type C soil includes cohesive soil with an unconfined compressive strength of 0.5 tsf or less; granular soils including gravel, sand, and loamy sand; and submerged soil or soil from which water is freely seeping.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1541.1 App A
48 / 60
A plumber breaks up concrete with a jackhammer, which produces impact noise. Under Title 8 Section 5096, exposure to impulsive or impact noise should not exceed what peak sound pressure level?
Title 8 Section 5096: exposure to impulsive or impact noise should not exceed 140 dB peak sound pressure level.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 5096
49 / 60
Under Title 8 Section 1514, how must personal protective equipment such as a hard hat be used?
Title 8 Section 1514: personal protective equipment shall be used in accordance with the manufacturer's instructions, and the employer shall require employees to use the required personal protective equipment.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1514
50 / 60
To repair a leaking valve, a plumber must cut into asbestos thermal system insulation (TSI) that is likely to be disturbed. Under Title 8 Section 1529, what class of asbestos work is this repair and maintenance operation?
Title 8 Section 1529: "Class III asbestos work" means repair and maintenance operations where ACM, including TSI and surfacing ACM and PACM, is likely to be disturbed.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1529
51 / 60
A plumber with long hair is about to run a drain machine with a rotating cable. Under Title 8 Section 3381, what must the plumber do where there is a risk of injury from hair entanglement in moving parts of machinery?
Title 8 Section 3381: where there is a risk of injury from hair entanglements in moving parts of machinery, combustibles or toxic contaminants, employees shall confine their hair to eliminate the hazard.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 3381
52 / 60
Under Labor Code Section 6311, may an employer lay off or discharge a plumber for refusing to perform work that would violate a safety order?
Labor Code Section 6311: no employee shall be laid off or discharged for refusing to perform work that would violate the code, any occupational safety or health standard, or any safety order, where the violation would create a real and apparent hazard to the employee or their fellow employees.
Source: Labor Code, cited sections LAB 6311
53 / 60
Workers must cross a sewer trench that is 8 feet deep and 4 feet wide to reach the job trailer. Under Title 8 Section 1541, what must be provided for them to cross?
Title 8 Section 1541: where employees or equipment are required or permitted to cross over excavations over 6 feet in depth and wider than 30 inches, walkways or bridges with standard guardrails shall be provided.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1541
54 / 60
Under Title 8 Section 1670, employees must wear approved personal fall arrest, fall restraint or positioning systems when their work exposes them to falling in excess of what distance from the perimeter of a structure?
Title 8 Section 1670: approved personal fall arrest, personal fall restraint or positioning systems shall be worn by employees whose work exposes them to falling in excess of 7 1/2 feet from the perimeter of a structure, unprotected sides and edges, or openings not otherwise adequately protected.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1670
55 / 60
A plumbing contractor finishes work in a sewer vault (a permit space) and cancels the entry permit. Under Title 8 Section 1954, how long must the contractor keep the canceled entry permit?
Title 8 Section 1954: the entry employer shall retain each canceled entry permit for at least 1 year, so the permit space program can be reviewed.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1954
56 / 60
Under Title 8 Section 3395, what must happen when a coworker shows signs or symptoms of heat illness on a hot job site?
Title 8 Section 3395: an employee exhibiting signs or symptoms of heat illness shall be monitored and shall not be left alone or sent home without being offered onsite first aid and/or being provided with emergency medical services in accordance with the employer's procedures.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 3395
57 / 60
Under the Title 8 Section 1504 definitions, fires involving energized electrical equipment are which class?
Title 8 Section 1504: Class C fires involve energized electrical equipment, where the electrical nonconductivity of the extinguishing media is of importance.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1504
58 / 60
Under Title 8 Section 2395.45, the exposed metal parts of hand-held motor-operated tools must be grounded. Which tool is excepted from that grounding requirement?
Title 8 Section 2395.45 lists hand-held motor-operated tools among the cord- and plug-connected equipment that shall be grounded. Its exception covers listed or labeled portable tools protected by an approved system of double insulation, which shall be distinctively marked.
Source: CCR Title 8 outside the Construction Safety Orders (General Industry, Electrical, and other safety orders), cited sections T8 2395.45
59 / 60
Work on a structure 40 feet above the ground cannot use personal fall arrest or other conventional protection, so a safety net is used. Under Title 8 Section 1671, how far below the work may the net be positioned?
Title 8 Section 1671: where the elevation is 25 feet or more and conventional protection is clearly impractical, an approved safety net extending at least 8 feet horizontally from the perimeter shall be positioned at a distance not to exceed 10 feet vertically below where the hazards exist.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1671
60 / 60
On a construction site, what is the maximum travel distance from any point of the protected area to the nearest fire extinguisher under Title 8 Section 1922?
Title 8 Section 1922: travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 75 feet.
Source: Cal/OSHA Construction Safety Orders (CCR Title 8, Subchapter 4) T8 1922